Figure 43: Display with ILEAK test result in SOCKET mode
1 ..... Selected function.
2 ..... Sub-result, mains voltage UL/N.
3 ..... Measurement screen touch-screen key.
4 ..... MODE touch-screen key to select measurement mode (SOCKET or CLAMP). Currently selected
mode is displayed on the bottom of the key.
5 ..... LIMIT touch-screen key to select limit leakage current. Currently selected value is displayed on the
bottom of the key.
6 ..... L POS touch-screen key to select the position of phase terminal on schuko socket during the
measurement. Currently selected position is displayed on the bottom of the key.
7 ..... Measurement result (in green colour - result OK, in red colour - result not OK).
8 ..... Real time clock (hh.mm.ss).
9 ..... Unit of the test result.
10 ... Measurement result status (symbol in green colour - result OK, symbol in red colour - result
not OK).