Ht-instruments HT712 Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 17
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
HT712
EN - 15
6.1.1. Electrical
Conversion TRMS
Display refreshing rate 3 times per second
6.1.2. Safety
The instrument complies with EN 61010-1
Insulation Class 2, Double insulation
Pollution degree 2
Overvoltage category CAT IV 600 V
For inside use, max height 2000m; 6561ft
6.1.3. General data
Mechanical characteristics
Dimensions 250(L) x 51(W) x 30(H)mm; 9.4 x 2.0 x 1.2in
Weight (including batteries) approximate 150g; 5.3ounces
Power supply
Battery type 2 batteries 1.5V AAA MN2400 LR03 AM4
Indication of low batteries " " is displayed when batteries voltage is too low
Battery life: Approximate 170 hours
Display
Type 3 ¾ digits LCD with max. reading 3999 counts +
symbol and decimal point
6.2. ENVIRONMENT
6.2.1. Environmental conditions
Reference temperature 23 ± 5°C; 73 ± 41°F
Working temperature 5 ÷ 40°C; 41 ÷ 104°F
Relative humidity <80%RH
Storage temperature -10 ÷ 60°C; 14 ÷ 140°F
Storage humidity <70%RH
This instrument complies with the European Directive on low voltage 2006/95/CE
(LVD) and with EMC 2004/108/CE
6.3. ACCESSORIES
6.3.1. Standard accessories
Instrument
Red test lead Code: P711EU
Black test lead Code: P710EU
Instruction manual
Bag Code: B700
Batteries
Note: accessories whose part number is not mentioned can not be reordered separately.